{"product_id":"io53a02-dc-5-24v-reversible-motor-controller","title":"IO53A02 DC 5–24V Forward Reverse Motor Controller – Reversible Driver Module for PLC Automation","description":"\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"detailmodule_dynamic\"\u003e\n \u003cbr\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003e\u003cspan style=\"font-size:22px\"\u003eProduct Name: DC 5-24V Multifunction AC DC Motor Reversible Controller Driver Board For Toy PLC Car Garage Door\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detailmodule_dynamic\"\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cdiv\u003e\n   \u003cspan style=\"font-size:14pt;font-family:verdana\"\u003ePackage inlcuded:\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cdiv\u003e\n   \u003cspan style=\"font-size:19px\"\u003e1 PCS\u003c\/span\u003e Multifunction AC\/DC motor Reversible controller\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S57421074a1c343968202f51c130e2c1eG.jpg\" slate-data-type=\"image\"\u003e\n \u003c\/div\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n \u003c\/div\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\u003cspan style=\"font-size:18pt\"\u003eDescription: \u003c\/span\u003e\n \u003c\/div\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e1 Dual power supply (two power supplies cannot be powered at the same time): \u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003ePower supply 1, DC 6.5-25V; Power supply 2, DC 5V\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"font-size:18px\"\u003e2 Working current: (Normal Mode) standby current 41mA, working current 82mA;\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e(Eergy-Saving mode) Standby current 7mA, working current 44mA.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"font-size:18px\"\u003e3 There are three input control ports: forward control(FWD), reverse control(REV), and stop control(STOP).\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"font-size:18px\"\u003e4 Two input trigger modes, Low-Pulse trigger mode, Low-Level trigger mode\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e5 Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"font-size:18px\"\u003e6 Cycle times: no cycle, 2-99 cycles, always cycle.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"font-size:18px\"\u003e7 Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED).\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"font-size:18px\"\u003e7 6 functional modes.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e8 Relay load current, recommended less than 5A.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"font-size:18px\"\u003e7 Size: 80*50*19mm\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e8 Weight: about 50 grams\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eThis is a multi-function DC\/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cstrong\u003e\u003cspan style=\"font-size:18px\"\u003ePort:\u003c\/span\u003e\u003c\/strong\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"font-size:18px\"\u003eDC 5.5MM female : Power supply 1, DC 5V power supply.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eVIN : Power 2 positive, DC 6.5-25V power supply\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eGND : Power supply 2 negative\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eFWD : Forward input control (partial Function-Mode is invalid)\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eREV : Reverse input control (partial Function-Mode is invalid)\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eSTOP : Stop input control (partial Function-Mode is invalid)\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eM+ : Motor positive \u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eM- : Motor negative\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eP+ : Positive motor power supply\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eP- : Negative motor power supply\u003c\/span\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"font-size:14pt\"\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cp\u003e\u003c\/p\u003e\n   \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px\"\u003eWiring:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n   \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793130947083yxa_1791108406706.jpg?v=1791108411\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n   \u003cp\u003e\u003c\/p\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    1 The working power supply is 6.5-25VDC. The motor is a DC 1-110V DC motor or AC 85-265V AC motor.\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793130948046dxy_1791108407641.jpg?v=1791108411\" slate-data-type=\"image\"\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    2 The working power supply is 5VDC. The motor is a DC 1-110V DC motor or an AC 85-265V AC motor.\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cp\u003e\u003c\/p\u003e\n    \u003cp style=\"text-align:left\" align=\"left\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793130949012sky_1791108408627.jpg?v=1791108413\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n    \u003cp style=\"text-align:left\" align=\"left\"\u003e\u003cspan style=\"color:rgb(0, 176, 240)\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:22px\"\u003eHow to use:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eQ\u0026amp;A:\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eQ1: Why is the digital tube not lit after power-on?\u003c\/p\u003e\n    \u003cp\u003eA1: This is because the ''Energy-Saving mode'' is set, please press and hold the OK button for 5 seconds to exit the energy saving mode.\u003c\/p\u003e\n    \u003cp\u003eQ2: Why does the motor not work after the motor is connected to the M+\/M- port?\u003c\/p\u003e\n    \u003cp\u003eA2: The working power and motor power of the board are independent. You need to supply power to the motor. The power port is P+\/P- port. It is recommended to use two separate power supplies for the working power supply and the motor power supply.\u003c\/p\u003e\n    \u003cp\u003eQ3: Why is the parameter setting invalid?\u003c\/p\u003e\n    \u003cp\u003eA3: After setting the parameters, be sure to re-power,Parameter settings can be saved permanently.\u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eTrigger mode:\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003e1 low pulse trigger (falling edge trigger)\u003c\/p\u003e\n    \u003cp\u003e2 low level trigger (rising edge trigger)\u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eT1: Forward timer\u003c\/p\u003e\n    \u003cp\u003eT2: Reverse timer\u003c\/p\u003e\n    \u003cp\u003eT3: Stop timer\u003c\/p\u003e\n    \u003cp\u003eTime unit : 0.1 second, 1 second, 1 minute\u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eRelay action:\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eMotor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing.\u003c\/p\u003e\n    \u003cp\u003eMotor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing..\u003c\/p\u003e\n    \u003cp\u003eMotor stop : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.\u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eFactory settings:\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003ePress the ''++'' and ''--'' buttons simultaneously for 5 seconds.\u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eEnergy-saving mode:\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003ePress and hold the ''OK'' button for 5 seconds to enter the ''Energy-saving mode''. Press and hold the ''OK'' button again for 5 seconds to exit the ''Energy-saving mode''. Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal.\u003c\/p\u003e\n    \u003cp\u003e\u003c\/p\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cp\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eFunction mode:\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eF-01\u003c\/p\u003e\n    \u003cp\u003eAfter power-on, the motor is forward T1 time; then the motor stops T3 time; then the motor reverse T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops working immediately. (FWD, REV port is invalid)\u003c\/p\u003e\n    \u003cp\u003eF-02\u003c\/p\u003e\n    \u003cp\u003eThis function is a F-01 variant. F-01 is run directly after power-on, but F-02 needs to trigger FWD or REV port to run.\u003c\/p\u003e\n    \u003cp\u003eF-11(Trigger reversible 1）\u003c\/p\u003e\n    \u003cp\u003eTrigger the FWD port, the motor is forward T1 time, and automatically stops (in order to protect the motor, during the delay period, trigger the REV port to stop T3 time and then reverse T2 time, trigger FWD port to re-time T1).\u003c\/p\u003e\n    \u003cp\u003eTrigger the REV port, the motor is reverse T2 time, and automatically stops (in order to protect the motor, during the delay period, the FWD port is triggered to stop the T3 time and then the T1 time is forward, and the REV port is re-timed T2).\u003c\/p\u003e\n    \u003cp\u003eWhen the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or reverse.\u003c\/p\u003e\n    \u003cp\u003eF-12(Trigger reversible 2）\u003c\/p\u003e\n    \u003cp\u003eTrigger the FWD port, the motor is forward T1 time and stops automatically (during the delay period, except for triggering STOP port, the other ports are invalid).\u003c\/p\u003e\n    \u003cp\u003eTrigger the REV port, the motor is reverses T2 time, and automatically stops (during the delay period, except for triggering STOP port, the other ports are invalid).\u003c\/p\u003e\n    \u003cp\u003eWhen the STOP port is trigger, the motor stops immediately, regardless of whether the motor is forward or reverse.\u003c\/p\u003e\n    \u003cp\u003eF-21\u003c\/p\u003e\n    \u003cp\u003eWhen the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.\u003c\/p\u003e\n    \u003cp\u003eWhen the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.\u003c\/p\u003e\n    \u003cp\u003eIn this mode, the FWD and REV ports cannot be connected low level at the same time, and the STOP port is invalid.\u003c\/p\u003e\n    \u003cp\u003eF-22\u003c\/p\u003e\n    \u003cp\u003eWhen the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.\u003c\/p\u003e\n    \u003cp\u003eWhen the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.\u003c\/p\u003e\n    \u003cp\u003eIn this mode, the FWD and REV ports cannot be connected low level at the same time, triggering the STOP port, the motor stops immediately.\u003c\/p\u003e\n    \u003cp\u003e\u003cstrong\u003eParameter setting:\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eThere are three menus: Work Menu, Function Menu, Parameter Menu.\u003c\/p\u003e\n    \u003cp\u003eNote: When entering the ''Function Menu'' or ''Parameter Menu'', the module still works normally (countdown and the trigger is running normally). The set parameters are valid only after being powered on again.\u003c\/p\u003e\n    \u003cp\u003e1 Power on to enter the running state (Work Menu).\u003c\/p\u003e\n    \u003cp\u003eIf the current function is F-01, then the motor direct run and the digital tube displays the countdown. F-01 is displayed after the operation is completed.\u003c\/p\u003e\n    \u003cp\u003eIf the current function is other functions, such as F-11. Then the digital tube displays F-11. After the trigger, the digital tube displays the countdown. After the operation is completed, F-11 is displayed.\u003c\/p\u003e\n    \u003cp\u003eDescription: The forward countdown F LED indicator flashes, the reverse countdown R LED indicator flashes, and the S LED indicator flashes when stopped.\u003c\/p\u003e\n    \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793130949968cmv_1791108409460.jpg?v=1791108414\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003cspan style=\"font-size:14pt\"\u003e2 In the running state(Work Menu), short press the SET button to enter the ''Function Menu'' (Above table).\u003c\/span\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793130950812bqw_1791108410341.jpg?v=1791108415\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003cspan style=\"font-size:14pt\"\u003e3 Press the ''SET'' button under ''Function Menu'' to enter the ''Parameter Menu''.(Above table)\u003c\/span\u003e\u003c\/p\u003e\n    \u003cp\u003eIn the ''Parameter Menu'', short press the ''SET'' button to select the parameters of 1-9, and set the parameters through the ''++'' button and the ''--'' button. Short press the ''OK'' button to save the current settings and return to the previous menu (Function Menu)\u003c\/p\u003e\n    \u003cp\u003eDescription:\u003c\/p\u003e\n    \u003cp\u003e1 Timer T1 T2 T3 time unit is 0.1 sec \/ sec \/ min, so the timing range of T1 T2 T3 is 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes\u003c\/p\u003e\n    \u003cp\u003e2 The number of cycles is the number of repeated actions (Nx =0 means always loop, Nx =1 means no loop). So you can set the number of loops: 1-99 times or forever loops.\u003c\/p\u003e\n    \u003cp\u003e3 F-21, F-22 function, Nx=1 parameter can not be changed\u003c\/p\u003e\n    \u003cp\u003e\u003c\/p\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"Eletechsup","offers":[{"title":"Default Title","offer_id":67644454633750,"sku":"IO53A02","price":10.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/S5bd2e8ef98b64288b4b76dd4463fa968Z.webp?v=1791108404","url":"https:\/\/eletee.com\/products\/io53a02-dc-5-24v-reversible-motor-controller","provider":"Eletechsup Direct Store","version":"1.0","type":"link"}