{"product_id":"n46ib02-2ch-4-20ma-rs485-modbus-adc-module","title":"N46IB02 2-Channel 4–20mA RS485 Modbus RTU Analog Input Module – 0–25mA 12-Bit ADC DC 12V","description":"\u003cp\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n \u003cbr\u003e\u003ckse:widget data-widget-type=\"customText\" id=\"4000000019774\" type=\"relation\"\u003e\u003c\/kse:widget\u003e\n \u003cbr\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003e\u003cspan style=\"font-size:22px\"\u003eProduct Name: 4-20MA To RS485 2 CH DC 12V 0-25MA Analog Acquisition Module 12Bit ADC Board Modbus RTU PLC\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\u003cspan style=\"font-size:14pt;font-family:Verdana\"\u003ePackage inlcuded:\u003c\/span\u003e\n  \u003c\/div\u003e \n  \u003cdiv\u003e\n   \u003cbr\u003e\n   1 x N46IB02 8-25V 2 CH 0-25MA Current analog acquisition RS485 module\n  \u003c\/div\u003e\n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793923258554pvo_1791900717964.jpg?v=1791900723\"\u003e\n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n   \n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\u003cspan style=\"font-size:18pt\"\u003eDescription: \u003c\/span\u003e\n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cdiv style=\"font-size:14pt\"\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     1: Operating Voltage : DC 8-25V(DC 9V 12V 15V 24V)\n     \u003cbr\u003e\n     \u003cbr\u003e\n     2: Operating Current : 9-13MA\n     \u003cbr\u003e\n     \u003cbr\u003e\n     3: MODBUS RTU Command support 03 06 function code\n     \u003cbr\u003e\n     \u003cbr\u003e\n     4: IN1\/IN2 channel current measurement range is 0-25MA(for 0-20MA\/4-20MA)\n     \u003cbr\u003e\n     \u003cbr\u003e\n     5: Current resolution is 0.1MA, measurement accuracy is 1%; if the error is greater than 1%, it can be calibrated\n     \u003cbr\u003e\n     \u003cbr\u003e\n     6 :MODBUS commands can be made serial HyperTerminal (serial assistant) OR PLC Enter;\n     \u003cbr\u003e\n     \u003cbr\u003e\n     7 :Under the MODBUS command mode, it can support up to 247 devices in parallel\n     \u003cbr\u003e\n     \u003cbr\u003e\n     8 :Size: 30 * 15 * 4.3mm(no PIN)\n     \u003cbr\u003e\n     \u003cbr\u003e\n     9 :Weight: 1.7g(no PIN),2.2g(with PIN)\n    \u003c\/div\u003e \n   \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"font-size:14pt\"\u003e\n   \u003cspan style=\"font-size:22px\"\u003e\u003cspan style=\"color:rgb(0, 0, 255)\"\u003eInstruction manual Please ask us after the purchase\u003c\/span\u003e\u003c\/span\u003e\n  \u003c\/div\u003e \n \u003c\/div\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cspan style=\"font-size:14pt\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n  4-20MA\/0-20MA Sensor\n  \u003cbr\u003e\n  \u003cbr\u003e\n  0-25MA Current analog acquisition\n  \u003cbr\u003e\n  \u003cbr\u003e\n  Automated industry PLC\n  \u003cbr\u003e\n  \u003cbr\u003e\n  Smart Home,Home Automation ;\n  \u003cbr\u003e\n  \u003cbr\u003e\n  Identification system;\n  \u003cbr\u003e\n  \u003cbr\u003e\n  RS485 Remote monitoring;\n  \u003cbr\u003e\n  \u003cbr\u003e\n  Multimeter voltmeter\n \u003c\/div\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n  Interface introduction\n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793923259358tjs_1791900718736.jpg?v=1791900721\" class=\"\" style=\"\"\u003e\n \u003c\/div\u003e \n \u003cdiv\u003e\n  \u003cbr\u003e\n   \n \u003c\/div\u003e \n \u003cdiv\u003e\n  \u003cbr\u003e\n   \n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\n  Wiring diagram\n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n   \n  \u003cp\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793923260108lca_1791900719517.jpg?v=1791900724\"\u003e\u003cbr\u003e\n   Slave ID: Different ''Sliver ID'' can be set by command, the maximum number is 247\u003cbr\u003e\n   Under the MODBUS command mode,the slave ID must be correct\u003cbr\u003e\n   Command Description, Please refer to '' N4AIA04 modbus rtu protocol ''\u003cbr\u003e\u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793923260882xey_1791900720242.jpg?v=1791900723\"\u003e\u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793923261717jsf_1791900721096.jpg?v=1791900728\"\u003e\u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1793923262450svl_1791900721806.jpg?v=1791900725\"\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003c\/p\u003e\n \u003c\/div\u003e \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n   \n  \u003cp\u003e\u003c\/p\u003e\n  \u003cp\u003e \u003c\/p\u003e\n  \u003cp\u003e\u003c\/p\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Eletechsup","offers":[{"title":"with Pin","offer_id":67708318122262,"sku":"N46IB02_A","price":4.79,"currency_code":"USD","in_stock":true},{"title":"no PIN","offer_id":67708318155030,"sku":"N46IB02_B","price":4.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/S53207e85293247ff97b1422381c01566U.webp?v=1791900715","url":"https:\/\/eletee.com\/products\/n46ib02-2ch-4-20ma-rs485-modbus-adc-module","provider":"Eletechsup Direct Store","version":"1.0","type":"link"}