{"product_id":"products-io23c01-8ch-30a-high-power-relay-module-dc24v","title":"IO23C01 8CH 30A High Power Relay Module – DC24V Multifunction Timer Delay Switch for PLC Motor Pump LED Control \u0026 Equipment Test","description":"\u003cp\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n \u003cbr\u003e\n \u003cdiv style=\"font-family:arial;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n  \u003cdiv style=\"font-size:0px;overflow:hidden\"\u003e\u003c\/div\u003e\n  \u003cbr\u003e\n \u003c\/div\u003e\n \u003cbr\u003e\n \u003cdiv style=\"font-family:arial;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\n  \u003cbr\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003e\u003cspan style=\"font-size:22px\"\u003eProduct Name: DC 24V 30A Multifunction Timer Delay Relay Module High Power On\/Off Adjustable For PLC Motor LED Pump\u003c\/span\u003e\u003c\/span\u003e\n  \u003cbr\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\u003cspan style=\"font-size:14pt;font-family:verdana\"\u003ePackage inlcuded:\u003c\/span\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\u003cspan\u003e1 PCS DC 24V 30A 1 channel multi-function delay relay module\u003c\/span\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cbr\u003e\n \u003c\/div\u003e\n \u003cbr\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n \u003cbr\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cbr\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\u003cimg width=\"800\" height=\"800\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sa3578ecd37dc438ab4953e331f38f959O.jpg\" slate-data-type=\"image\"\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\u003cimg width=\"1000\" height=\"1000\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1786194462400pdq_1784171921766.jpg?v=1784171924\" slate-data-type=\"image\"\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\u003cspan\u003e\u003cspan style=\"font-size:18pt\"\u003eDescription: \u003c\/span\u003e\u003c\/span\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cbr\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cbr\u003e\n  \u003cdiv\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cbr\u003e\n  \u003cdiv style=\"color:rgb(255, 0, 0)\"\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:14pt\"\u003eIO23C01\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003emultifunction relay control module, designed specifically for a variety of users with different needs, the use of micro-controller as the primary\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eControl unit, preset 18 kinds of functions, and can be based on user needs, customize and add other specific functions.\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eGenuine high quality power relay modules, high power high-voltage transistor, red, blue signal lights, military grade double-sided\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003ePCB board, cloth board to consider a comprehensive, stable performance, can be widely used in a variety of power control type applications.\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFeatures:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     1 new upgrade to version 3.0, the module functions by eight kinds before, increased to 18 kinds, to meet the needs of more applications;\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     2 Power is DC 24V\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     3 uses top-quality high-voltage power supply modules, discrete power supply before replacing the system more stable and reliable;\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     4 increased 0.1 seconds timing, timing accuracy from the previous 0.1 seconds, upgrade to 0.01 seconds;\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     5 increase in automatic power saving feature, users can independently set.\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     6.Size:80x37x24mm\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     7 Weight : 46 grams\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eModule Functions:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eTips: Function 1-8 on power-up self-start function 9-18 require high pulse signal (high duration is shorter than 20ms, hereinafter the same) trigger the start.\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 1:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eTiming Pick: After power, time delay relay pull T1, T1 between 0.1 seconds -270 hours adjustable, IN interface to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal, repeat the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 2:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eTiming off: when the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, IN interface to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal, repeat the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 3:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eTiming pull off again: After power relay to not pull, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 in 0.1 seconds -270 hours between adjustable, CH1 interface to a\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003epulse signal, repeat the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 4:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eTiming and then pull off: After power, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, -270 hour in 0.1 seconds delay time between T1 and T2 adjustable to CH1 interface a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003epulse signal, repeat the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 5:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eInfinite loop timing mode 1: After power relay to not pull, after the delay time T1 reaches the relay is energized; pull the relay off after time T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 adjustable between second -270 hours, giving a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal CH1 interface, you can restart the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 6:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eInfinite loop timing mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting time T2 relay, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, giving a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal CH1 interface, you can restart the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 7:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFinite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003epulse signal, the above functions can be re-started;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 8:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFinite loop timing mode 2: 6, on the basis of the function, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003epulse signal, the above functions can be re-started;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 9:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eLatching relay modes: CH1 interface to relay a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal, relay, give a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003epulse signal relay disconnected.\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 10:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eTrigger relay modes: CH1 interface to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003esignal relay, relay, \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003elow \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003edisappear, relay disconnected.\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 11:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003ePull the trigger timing: After power relay does not act, a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003e-level interface to CH1 pulse signal, the delay time relay pull T1, T1 between 0.1 seconds -270 hours adjustable, repeating a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel interface to CH1 pulse signal, repeat the above function;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 12:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eTrigger timing off: After power relay does not act, a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003e-level interface to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 interface a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003epulse signal, repeat the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 13:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003ePull the trigger timing then disconnect: After power relay does not act, CH1 interface to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 between 0.1 seconds -270 hours adjustable, repeat CH1 interface to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal, repeat the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 14:\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eDisconnect and then pull the trigger timing: After power relay does not act, a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003e-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal, repeat the above functions;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 15:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eInfinite loop timing mode 1: After power relay does not operate to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal CH1 interface, the delay time T1 reaches the relay is energized; pull off the relay arrival time T2, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal, the above functions can be re-started;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color: rgb(0, 0, 0);\"\u003eFunction 16:\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eInfinite loop timing mode 2: After power relay does not act, a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003e-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; break time T2 after reaching relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003elevel pulse signal, the above functions can be re-started;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 17:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFinite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003epulse signal, the above functions can be re-started;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFunction 18:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003eFinite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0);font-size:19.09px\"\u003ehigh \u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003epulse signal, the above functions can be re-started;\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cimg width=\"800\" height=\"481\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1786194463083szj_1784171922458.jpg?v=1784171925\" slate-data-type=\"image\"\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 176, 240)\"\u003eConnections:\u003c\/span\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     Module Voltage Signal Input:There have three interfaces, all interfaces have terminal,user easy to use.\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     1.GND : DC 24V Negative\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     2.12V : DC 24V Positive\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     3.IN1:Input signal interface. (2.5-24V high voltage to be valid; 0-0.6V low voltage to be invalid;0.7V-2.4V voltage is unpredictable,you should avoid this voltage range)\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     Module Output: There have three interfaces, all interfaces have terminal.\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     1.NO : Normally open interface,the relay becomes vacant before, after pull-in short with the COM;\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     2.COM : Common interface;\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cbr\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cdiv style=\"font-size:14pt\"\u003e\n   \u003cdiv\u003e\n    Module Size\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     1. Dimensions: 80mm * 37mm * 24mm (L * W * H);\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     4. Weight : 46g\n     \u003cbr\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:36px\"\u003e\u003cspan style=\"color:rgb(192, 0, 0)\"\u003eFor more information, please contact me !!!\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n   \u003c\/div\u003e\n   \u003cbr\u003e\n  \u003c\/div\u003e\n  \u003cbr\u003e\n \u003c\/div\u003e\n \u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Eletechsup","offers":[{"title":"Default Title","offer_id":51564467355926,"sku":"IO23C01_24V","price":11.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/900096202607161118306a584d8685ed6.png?v=1784171924","url":"https:\/\/eletee.com\/products\/products-io23c01-8ch-30a-high-power-relay-module-dc24v","provider":"Eletechsup Direct Store","version":"1.0","type":"link"}