{"product_id":"products-sgiob08-8di-8do-rs485-modbus-rtu-safety-barrier","title":"SGIOB08 Ultra-Thin Safety Barrier IO Module – 8DI-8DO RS485 Modbus RTU with 3000VDC Isolation for PLC Industrial Equipment","description":"\u003cp\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n \u003cbr\u003e\n \u003cbr\u003e\u003cspan style=\"font-size:22px\"\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003eProduct Name: Ultra-thin Safety Barrier Module RS485 IO 8DI-8DO Isolated Digital Input Output MODBUS RTU for Relay PLC Industrial Equipment\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n  \n \u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cbr\u003e\u003cspan style=\"font-size:14pt;font-family:verdana\"\u003ePackage inlcuded:\u003c\/span\u003e\n    \u003c\/div\u003e \n    \u003cdiv\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     1 PCS DC 7-30V 8DI-8DO Safety Barrier RS485 Digital Input \u0026amp; Output IO Module\n    \u003c\/div\u003e\n   \u003c\/div\u003e \n   \u003cdiv\u003e\n    \u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1790185256718rkr_1788162716065.jpg?v=1788162719\"\u003e\n   \u003c\/div\u003e \n   \u003cdiv\u003e\n    \u003cbr\u003e\n     \n   \u003c\/div\u003e \n   \u003cdiv\u003e\n    \u003cbr\u003e\n     \n   \u003c\/div\u003e \n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cstrong\u003e1 Product description\u003c\/strong\u003e\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e8ch optoelectronic isolation digital input channel (NPN Low level input)\u003cbr\u003e\n     8ch optoelectronic isolation digital output channel (ULN2803 NPN output)\u003cbr\u003e\n     RS485 MODBUS RTU standard communication protocol\u003cbr\u003e\n     Netted with configuration software, PLC or industry touch panel\u003cbr\u003e\n     Communication circuit designed for thunder protection and interference immunity\u003cbr\u003e\n     Used for signal collection and control in industrial field\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cstrong\u003e2 Specification\u003c\/strong\u003e\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e1 Working voltage: DC 7-25V (9V 12V 24V)\u003cbr\u003e\n     2 Working current: 8-50MA\u003cbr\u003e\n     3 8 port optically isolated input ports (NPN active low)\u003cbr\u003e\n     4 8 port Darlington tube outputs (ULN2803 NPN output), the maximum load current of each channel is 300MA\u003cbr\u003e\n     5 RS485 communication isolation protection 3000VDC, DI digital input port isolation protection 3000VDC\u003cbr\u003e\n     6 Standard MODBUS RTU command (function code, 05\/06\/15\/16 Write, 01\/02\/03 Read )\u003cbr\u003e\n     7 Baud rates: 1200 2400 4800 9600 (default) 19200 38400 57600 115200\u003cbr\u003e\n     8 Parity bits: None (default) \/Even \/Odd\u003cbr\u003e\n     9 Installation method Standard DIN rail installation\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    10 Size : 125×110×22mm\n    \u003cbr\u003e\n    \u003cbr\u003e\n    11 Weight: 130 grams\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style=\"color:rgb(0, 0, 255)\"\u003e\u003cstrong\u003e3 Interface definition:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"color:rgb(0, 0, 255)\"\u003e\u003cspan style=\"font-size:18px\"\u003eVi : Power input+\u003cbr\u003e\n      G: Power input-\u003cbr\u003e\n      Vo: =Vi\u003cbr\u003e\n      DO1: digital output channel 1\u003cbr\u003e\n      DO2: digital output channel 2\u003cbr\u003e\n      DO3: digital output channel 3\u003cbr\u003e\n      DO4: digital output channel 4\u003cbr\u003e\n      DO5: digital output channel 5\u003cbr\u003e\n      DO6: digital output channel 6\u003cbr\u003e\n      DO7: digital output channel 7\u003cbr\u003e\n      DO8: digital output channel 8\u003cbr\u003e\n      DI1 : Digital input channel 1\u003cbr\u003e\n      DI2 : Digital input channel 2\u003cbr\u003e\n      DI3 : Digital input channel 3\u003cbr\u003e\n      DI4 : Digital input channel 4\u003cbr\u003e\n      DI5 : Digital input channel 5\u003cbr\u003e\n      DI6 : Digital input channel 6\u003cbr\u003e\n      DI7 : Digital input channel 7\u003cbr\u003e\n      DI8 : Digital input channel 8\u003cbr\u003e\n      A+: RS485 signal A+\u003cbr\u003e\n      B-: RS485 signal B-\u003c\/span\u003e\u003c\/span\u003e\n   \u003c\/div\u003e \n   \u003cdiv\u003e\n     \n    \u003cdiv style=\"font-size:14pt\"\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\n     \u003cbr\u003e\u003cspan style=\"font-size:24px\"\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003eFor more information, please contact me\u003c\/span\u003e\u003c\/span\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e \n   \u003cdiv\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:14pt\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003ePLC DIO Output expansion board\u003cbr\u003e\n     Smart Home,Home Automation ,Wiser Home;\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003ePTZ CCTV Camera\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003eSecurity Monitoring\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003eIdentification system;\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003eMotor FW \u0026amp; BW\u003cbr\u003e\n     Automatic curtain control\u003cbr\u003e\n     Relay Solenoid valve\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e1 NPN Digital Input Wiring Diagram\u003cbr\u003e\n     2 NPN Digital output wiring diagram\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003eNote: The Darlington tube has only two states of ''high resistance'' and ''conduction'', and the output level cannot be measured with a multimeter.\u003c\/span\u003e\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S1d87d81016f646819afd087a24fae3511.jpg\"\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1790185258091uuv_1788162717401.jpg?v=1788162720\"\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:18px\"\u003eRS485 Networking Diagram\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1790185258758udp_1788162718066.jpg?v=1788162723\"\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003eModbus Rtu Register:\u003c\/span\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\n    \u003cbr\u003e\u003cimg slate-data-type=\"image\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/1790185259491sdw_1788162718784.jpg?v=1788162726\"\u003e\n   \u003c\/div\u003e \n   \u003cdiv\u003e\n    \u003cbr\u003e\n     \n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Eletechsup","offers":[{"title":"Default Title","offer_id":51807838667030,"sku":"SGIOB08","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/4063\/8742\/files\/S7c4aa793e0ee4769ad8a31cf451ec314G.webp?v=1788162714","url":"https:\/\/eletee.com\/products\/products-sgiob08-8di-8do-rs485-modbus-rtu-safety-barrier","provider":"Eletechsup Direct Store","version":"1.0","type":"link"}