1
/
of
9
23IOB16 16-Channel RS485 Remote I/O Module – NPN Opto-Isolated Input & 300mA Solid-State Output DC 12V/24V
23IOB16 16-Channel RS485 Remote I/O Module – NPN Opto-Isolated Input & 300mA Solid-State Output DC 12V/24V
Regular price
$15.99 USD
Regular price
$22.83 USD
Sale price
$15.99 USD
Taxes included.
Product Name: 23IOB16 16-Channel RS485 Remote I/O Module – NPN Opto-Isolated Input & 300mA Solid-State Output DC 12V/24V
Package inlcuded:
1PCS DC12V-24V 16
NPN Input& 16 NPN Output RS485 IO Module
1PCS DC12V-24V 16
NPN Input& 16 NPN Output RS485 IO Module
Description:
1 Working voltage: DC 6.5-30V (9V 12V 24V)
2 Working current: 8-50MA
3 16 optically isolated input ports, NPN input
4 16 Darlington transistor outputs (ULN2803 NPN output)
5 The default command has a variety of output modes: ''open'' ''close'' ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands
6 The i
nput port can remotely control output port of another board via RS485 bus (relevant registers must be set)
7 MODBUS command 1 supports 03 06 16 function codes, MODBUS command 2 supports 01/02/03/05/06/15/16 function codes
8 The maximum delay of 1 MODBUS command is 255 seconds
9 In MODBUS command mode, up to 64 devices can be used in parallel
10 The default baud rate is 9600BPS, you can choose the baud rate by jumper:
1200/2400/4800/19200/38400/57600/115200BPS
11 Sizes (with box):130x80x30mm
12 Weight (with box):148g
13 Maximum load: the maximum load current of each channel is 300MA
For more information, please contact me
2 Working current: 8-50MA
3 16 optically isolated input ports, NPN input
4 16 Darlington transistor outputs (ULN2803 NPN output)
5 The default command has a variety of output modes: ''open'' ''close'' ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands
6 The i
nput port can remotely control output port of another board via RS485 bus (relevant registers must be set)
7 MODBUS command 1 supports 03 06 16 function codes, MODBUS command 2 supports 01/02/03/05/06/15/16 function codes
8 The maximum delay of 1 MODBUS command is 255 seconds
9 In MODBUS command mode, up to 64 devices can be used in parallel
10 The default baud rate is 9600BPS, you can choose the baud rate by jumper:
1200/2400/4800/19200/38400/57600/115200BPS
11 Sizes (with box):130x80x30mm
12 Weight (with box):148g
13 Maximum load: the maximum load current of each channel is 300MA
For more information, please contact me
Application
PLC IO expansion board
Smart Home,Home Automation ,Wiser Home;
PTZ Camera
Security Monitoring
Identification system;
IP Camera
LED Lamp Drivers
Automatic curtain control
Smart Home,Home Automation ,Wiser Home;
PTZ Camera
Security Monitoring
Identification system;
IP Camera
LED Lamp Drivers
Automatic curtain control
Application 1: Control 16 channel switch output through RS485 bus
Application 2: Read 16 channel switch input via RS485 bus
Application 3: 16 channel input remote control 8/16/24/32/48 channel output